Product names:  HKCPT61CE
Products Introduced:

HKCPT61CE-wear - horizontal precision small AC voltage transformer current GM

First, characteristics:
1, the voltage transformer can be used for current transformer can be used;
2, completely closed, mechanical and environmental performance and resistance, voltage isolation, and a strong ability pleasing in appearance;
3, Horizontal wear batteries, printed circuit board directly welding installation;
4, led by 2.54 mm pin spacing grid with, adapt to the computer cloth panels;
5, compact portable, high accuracy, wide sampling scope, application flexibility.

Second, security features:
1 insulation resistance: the norm than 1,000 megohms;
2-voltage strength: for when 4000 V voltage transformer / 1 minute For the current transformer when the 6000 V / 1 minute
3 flame retardant: meet UL94 - Vo -

Third, contour map, installation size and coil Banner:


Fourth, performance parameters:
1, a voltage transformer used:
HKCPT61CE for voltage transformer is used when a current-voltage transformer, a typical application and the map in figure 2. Performance parameters see Table 1;

                   
Table 1:

Use

Input voltage

Output voltage

Phase shift

Nonlinearity

linear range

Rated Current

Pressure

Figure 1 Act

≤1000Vac

≤1.2V

≤30’

≤0.2%

1.5times Rated

6mA/6mA

≥3KV

Figure 2 Act

≤1000Vac

≤1/2times the supply voltage IC

≤5’

≤0.1%

2times Rated









2, a current transformer used:

HKCPT61CE for current transformer application, as long as users followed in the four-application method, as follows Figure III, IV, V, VI. The performance parameters shown in the table below and in Table 3. Heart hole wearing 1-Turn bus as input coil,

Table 2:

use

Rated Importation Current

Rated Output Current

Rated Sampling resistance

Rated Sampling voltage

Phase shift

Nonlinearity

linear range

Pressure

Figure 3 Act

9A

6mA

200Ω

1.2V

≤30’

≤0.2%

1.5times Rated

≥6KV

Figure 4 Act

18A

6mA

400Ω

2.4V

≤20’










Table 3:

use

Rated Importation
Current

Rated Output
Current

Rated Sampling voltage

Phase shift

Nonlinearity

linear range

Pressure

Figure 5 Act

9A

6mA

≤1/2times the supply voltage IC

≤5’

≤0.1%

≥2times Rated

≥6KV

Figure 6 Act

18A

6mA








Fifth. Note:
Regardless of the type transformer voltage transformer for use, or for the use of current transformer, and its principles are current-mode transformer, secondary circuit does not allow the use of open, but also because of this, please do not install Fuse in the secondary loop .